|
Analog Devices Inc. |
IC SUPERVISOR MPU RESET SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 1.67V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 4.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 4.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 4.38V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 4.38V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 2.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 2.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 2.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 2.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR P/P 2.93V SC70-4 |
Obsolete | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 2.93V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 2.93V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 2.93V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 3.08V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 3.08V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 2.32V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 2.32V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR OD 4.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 4.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR OD 4.38V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 4.38V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR OD 2.63V SC70-4 |
Obsolete | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 2.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 2.63V SC70-4 |
Obsolete | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 2.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 2.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 2.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 2.93V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 2.93V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR OD 2.32V SC70-4 |
Obsolete | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 2.32V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR MPU 2.32V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 2.32V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR WATCHDOG LV SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 1.67V | -40°C ~ 85°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR WATCHDOG LV SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 2.63V | -40°C ~ 85°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Analog Devices Inc. |
IC SUPERVISOR WATCHDOG LV SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 1 ms Minimum | 2.93V | -40°C ~ 85°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 1.58V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 1.58V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.31V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 2.31V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 1.12 s Minimum | 2.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 1.12 s Minimum | 2.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.93V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 1 ms Minimum | 2.93V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.93V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 2.93V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 4.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 4.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 1.58V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 1.58V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.31V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 2.31V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 20 ms Minimum | 2.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.93V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 2.93V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 3.08V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 3.08V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 4.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 4.63V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.63V SC70-4 |
Active | Multi-Voltage Supervisor | 2 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 2.63V, Adj | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.93V SC70-4 |
Active | Multi-Voltage Supervisor | 2 | Push-Pull, Totem Pole | Active Low | 140 ms Minimum | 2.93V, Adj | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 3.08V SC70-4 |
Active | Multi-Voltage Supervisor | 2 | Open Drain or Open Collector | Active Low | 20 ms Minimum | 3.08V, Adj | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 3.20V SC70-4 |
Active | Multi-Voltage Supervisor | 2 | Open Drain or Open Collector | Active Low | 1 ms Minimum | 3.2V, Adj | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 3.20V SC70-4 |
Active | Multi-Voltage Supervisor | 2 | Open Drain or Open Collector | Active Low | 20 ms Minimum | 3.2V, Adj | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.93V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 1.12 s Minimum | 2.93V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 3.08V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 1.12 s Minimum | 3.08V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 3.08V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 1.2 s Minimum | 3.08V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 1.575V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | Adjustable/Selectable | 1.575V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.188V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | Adjustable/Selectable | 2.188V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.925V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | Adjustable/Selectable | 2.925V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 4.80V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active Low | Adjustable/Selectable | 4.8V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 1.575V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Push-Pull, Totem Pole | Active High | Adjustable/Selectable | 1.575V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 1.575V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | Adjustable/Selectable | 1.575V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.188V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | Adjustable/Selectable | 2.188V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC 2.63V SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | Adjustable/Selectable | 2.625V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |
|
Maxim Integrated |
IC MPU/RESET CIRC SC70-4 |
Active | Simple Reset/Power-On Reset | 1 | Open Drain or Open Collector | Active Low | 140 ms Minimum | 3.08V | -40°C ~ 125°C (TA) | Surface Mount | SC-82A, SOT-343 | SC-70-4 |