Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 16A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 16A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 16A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 16A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 16A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 16A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 520/300VAC 8A DIN |
Active | Single Phase | Single Stage | - | 520V, 300V | - | - | 8A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 500VAC 4A CHASSIS |
Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 4A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
Active | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Wire Leads | - |
|
Cosel USA, Inc. |
LINE FILTER 500VAC 10A CHASSIS |
Active | Three Phase (Delta) | Single Stage | - | 500V | - | - | 10A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 20A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 20A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 20A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 20A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 20A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 20A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 20A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 20A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 250VDC/VAC 20A CHAS |
Active | Single Phase | Two Stage | 250V | 250V | 250V | - | 20A | - | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
EPCOS (TDK) |
LINE FILTER 530/305VAC 3A CHAS |
Active | Three Phase (Delta) | Single Stage | - | 530V, 305V | - | - | 3A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
EPCOS (TDK) |
LINE FILTER 250V 30A CHASSIS MNT |
Active | Single Phase | Two Stage | - | - | - | - | 30A | - | General Purpose | cULus, ENEC | - | Chassis Mount | Terminal Block | - |
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
Active | Single Phase | Single Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | - |
|
EPCOS (TDK) |
LINE FILTER 530/305VAC 17A CHASS |
Active | Three Phase (Delta) | Single Stage | - | 530V, 305V | - | - | 17A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
KEMET |
LINE FILTER 7A CHASS MNT |
Active | Three Phase (Delta) | Single Stage | - | - | 305V | 530V | 7A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 250VAC 8A CHASS MNT |
Active | Single Phase | Single Stage | - | 250V | - | - | 8A | DC ~ 400Hz | Regenerative Motor Drive | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
KEMET |
LINE FILTER 440VDC 250VAC CHAS |
Active | Single Phase | Single Stage | 440V | 250V | - | - | 300A | 50/60Hz | General Purpose | UR | -40°C ~ 85°C | Chassis Mount | Threaded Post (M12) | - |
|
KEMET |
LINE FILTER 750VDC 440VAC CHAS |
Active | Single Phase | Single Stage | 750V | 440V | - | - | 300A | 50/60Hz | General Purpose | UR | -40°C ~ 85°C | Chassis Mount | Threaded Post (M12) | - |
|
Schaffner EMC Inc. |
LINE FILTER 50A DIN RAIL |
Active | Three Phase (Delta) | Single Stage | - | - | 300V | 520V | 50A | 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
KEMET |
LINE FILTER 25A CHASS MNT |
Active | Three Phase (Wye) | Single Stage | - | - | 305V | 530V | 25A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
EPCOS (TDK) |
LINE FILTER 480/275VAC 16A CHASS |
Active | Three Phase (Delta) | Single Stage | - | 480V, 275V | 275V | 480V | 16A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, ENEC, UL | - | Chassis Mount | Terminal Block, Threaded Post (M6) | - |
|
Cosel USA, Inc. |
LINE FILTER 500VAC 50A CHASSIS |
Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 50A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Cosel USA, Inc. |
LINE FILTER 500VAC 50A CHASSIS |
Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 50A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 520/300VAC 80A CHASS |
Active | Single Phase | Single Stage | - | 520V, 300V | - | - | 80A | 250Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
KEMET |
LINE FILTER 75A CHASS MNT |
Active | Three Phase (Delta) | Single Stage | - | - | 305V | 530V | 75A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 30A CHASSIS MOUNT |
Active | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 30A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
TE Connectivity Corcom Filters |
LINE FILTER 36A CHASSIS MOUNT |
Active | Three Phase (Wye) | Single Stage | - | - | 250V | 440V | 36A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Threaded Post (10-32) | - |
|
Schaffner EMC Inc. |
LINE FILTER 480VAC 64A CHASS MNT |
Active | Three Phase (Wye) | Single Stage | - | 480V | 300V | 520V | 64A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 1.2KVDC 150A CHASS |
Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 150A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 250VAC 20A CHASS MNT |
Active | Single Phase | Three Stage | - | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | UR | -25°C ~ 85°C | Chassis Mount | Terminal Block | 3.5mH |
|
Schaffner EMC Inc. |
LINE FILTER 8A CHASSIS MOUNT |
Active | Three Phase (Delta) | Single Stage | - | - | - | - | 8A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 6.9mH |
|
TE Connectivity Corcom Filters |
LINE FILTER 12A CHASSIS MOUNT |
Active | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 12A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 10A CHASSIS MOUNT |
Active | Three Phase (Delta) | Single Stage | - | - | - | - | 10A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 5.2mH |
|
Schaffner EMC Inc. |
LINE FILTER 55A CHASSIS MOUNT |
Active | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 55A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 8A CHASSIS MOUNT |
Active | Three Phase (Delta) | - | - | - | 288V | 500V | 8A | - | General Purpose | - | -25°C ~ 70°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 4.5A CHASSIS MOUNT |
Active | Three Phase (Delta) | Single Stage | - | - | - | - | 4.5A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 13mH |
|
Schaffner EMC Inc. |
LINE FILTER 55A CHASSIS MOUNT |
Active | Three Phase (Delta) | Two Stage | - | - | 400V | 690V | 55A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
Active | Single Phase | Three Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Wire Leads | - |
|
TE Connectivity Corcom Filters |
LINE FILTER 80A CHASSIS MOUNT |
Active | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 80A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
TE Connectivity Corcom Filters |
LINE FILTER 150A CHASSIS MOUNT |
Active | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 150A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 8A CHASSIS MOUNT |
Active | Three Phase (Delta) | Single Stage | - | - | - | - | 8A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 6.9mH |
|
Schaffner EMC Inc. |
LINE FILTER 17A CHASSIS MOUNT |
Active | Three Phase (Delta) | Single Stage | - | - | - | - | 17A | - | Regenerative Motor Drive | cURus | -25°C ~ 70°C | Chassis Mount | Terminal Block | 3.1mH |
|
TE Connectivity Corcom Filters |
LINE FILTER 130A CHASSIS MOUNT |
Active | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 130A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | - |
|
Schaffner EMC Inc. |
LINE FILTER 75A CHASSIS MOUNT |
Active | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 75A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |